GSP-810
(150kHz ~ 1000MHz)

 

FEATURES:
yball.gif (937 bytes) Frequency Range : 150kHz ~ 1000MHz
yball.gif (937 bytes) Fully Digital Phase Locked Loop Technique Design
yball.gif (937 bytes) High Frequency Stability : 10ppm
yball.gif (937 bytes) High Resolution of Span to Measure the more detailed signal : 
    Zero,  2kHz ~ 100MHz /DIV
 
yball.gif (937 bytes) RBW : 3k, 30k, 220k, 4M
yball.gif (937 bytes) High Input Protection Level : +30dBm, +25VDC
yball.gif (937 bytes) Reference Level Range : -30dBm ~ +20dBm
yball.gif (937 bytes) Good Noise Floor Performance : -95dBm @30kHz, -100dBm
    typical ; over -150dBm/Hz typical @220kHz and 4MHz RBW
yball.gif (937 bytes) Spurious Noise : < -60dB
yball.gif (937 bytes) Inter-modulation (3rd) : < -70dBc
yball.gif (937 bytes) Two Markers for Absolute and Relative Measurement
yball.gif (937 bytes) Functions : Max. Hold, Average (2 ~ 32 traces), Freeze, Peak Search, Marker to   Center Function
yball.gif (937 bytes) 9 Memories of Save/Recall
yball.gif (937 bytes) RS-232 Interface and Display Software to get Trace from GSP-810
    to PC
yball.gif (937 bytes) Options :Power Meter, Tracking Generator, Remote Control     Software
 

      FREQUENCY
      Frequency Range 150kHz ~ 1000MHz
      Frequency Resolution 1kHz C.F. entry, 40Hz Sweep resolution at 2kHz/DIV
      Frequency Display 6 1/2 digit setting
      Frequency Control Digital phase locked
      Frequency Stability + 2ppm/year aging,+10ppm, 0 to 50C
      Frequency Spans Zero, 2kHz to 100MHz/DIV, in a 1-2-5 sequence

      BANDWIDTH
      Resolution Bandwidths 3kHz,30kHz, 220kHz, 4MHz
      Resolution BW Accuracy 15%
      Video Bandwidth 1.6kHz/90kHz coupled with RBW

      AMPLITUDE
      Reference Level Range -30dBm to +20dBm
      Reference Level Accuracy + 1dB at 80MHz
      Input Level Range -100dBm to +20dBm
      Noise Floor -95dBm@30kHz RBW, -100dBm typical/-75dBm:150kHz ~ 10MHz
      Amplitude Display Range 75dB
      Amplitude Accuracy + 1.5dB typical@0dBm, 80MHz
      Amplitude Level Linearity + 1.5dB over 70dB
      Ref. Level Freq. Flatness + 1.5dB over 100MHz, ฑ2.5dB typical over entire band/ฑ3dB:150kHz ~10MHz
      Harmonic Spur Response <-40dBc, RF input < selected reference
      Non-Harmonic Spur Response <-60dBc typical down from reference level, average, 5MHz/div
      Intermodulation(3rd) <-70dBc, @-40dBm input, 2 tones, 2MHz apart/<-45dBc:150kHz ~10MHz
      Phase Noise -77dBc/Hz at 1GHz, 30kHz offset

      INPUT
      Input Overload Protection +30dBm continuous, +25VDC
      Impedance 50 ohm nominal
      Return Loss <16 dBRL (VSWR < 1.35)
      Input Attenuation 50dB to 0dB in 10 dB steps coupled to reference level
      Connector Type N female

      MARKER
      Number of Markers 2
      Marker Resolution 0.1dB, 1kHz
      Marker Mode Absolute, Relative, PK -> Marker, Marker -> Center
      Marker Accuracy 0.1dBฑamplitude accuracy

      FUNCTIONS
      Memory 9 memories of save/recall
      Trace Max. Hold, Average(2 ~ 32 traces), Freeze (Hold)
      Setup Access parameters

      FM/AM DEMODULATOR
      WB FM 120kHz deviation
      MB FM 75kHz deviation
      NB FM 30kHz deviation
      AM Outputs Internal speaker, 3.5mm stereo jack, wired for mono operation

      REMOTE DISPLAY SOFTWARE & RS-232
      Connecting to PC and getting trace from GSP-810

      GENERAL
      Power Source 100/120/220/230V AC+10%, 50/60Hz
      Accessory Operation manual x 1
      Dimensions and Weight 310(W) x 150(H) x 455(D)mm, approx. 8.5kg

      OPTIONS
     
     
TRACKING GENERATOR (OPTION 01)
      Frequency Range 10MHz to 1000MHz
      Amplitude Range 0 to -50dBm
      Amplitude Resolution 1dB
      Amplitude Accuracy + 1dB@0dBm, 80MHz
      Attenuation Accuracy + 1dB@, 50MHz
      Amplitude Flatness + 1dB@, 10MHz/DIV, +1.5dB@0dB,entire band
      Harmonics <-30dBc
      Reverse Power <+30dBm
      Impedance 50 ohm nominal
      Return Loss <10 dBRL (VSWR<2)
      Connector Type N female

      POWER METER (OPTION 02)
      Frequency Range 10MHz to 2GHz, usable to 2.7GHz
      Power Level Range -20dBm to +23dBm, usable to +30dBm
      Power Level Overload +40dBm<10% duty cycle, <10mS duration
      Return Loss <1:1.35 VSWR into 50 ohms, <1:1.25 typical
      Readout Resolution 0.2mW, 100mW scale, 2ตW, 1mW scale; 0.1dB, Log scale
      Accuracy + (10% rdg +1digit)
      Readout mW or dBm

      REMOTE CONTROL SOFTWARE (OPTION 03)

      Connecting PC to get trace and provide the control for setting


   
--------------------------------------------------------------------------------------------------------------------------------------------------------------------- TOP
.......................................................................................................................................................................................................................................................................

Copyright (C) 2006 SC INTERNATIONAL RESEARCH CO., LTD. All Rights Reserved.
63/2772 Rajpattana Road, Sapansung, Sapansung, Bangkok 10240
Tel. (66)0-2948-7398 Fax (66)0-2948-7398