Generation Analog Oscilloscope

nce.jpg (1984 bytes)


New GOS-6000 Series 

FEATURES:
yball.gif (937 bytes) 2 Channels, 4 Traces:
    DC ~ 30MHz (GOS-6030/6031)
    DC ~ 50MHz (GOS-6050/6051)
yball.gif (937 bytes) 1mV/DIV ~ 20V/DIV
yball.gif (937 bytes) CRT Readout
yball.gif (937 bytes) Cursor Measurement, 6 Digit Frequency Counter, 10 Sets Memory for Front Panel
    Setting Save & Recall (GOS-6031/6051)
yball.gif (937 bytes) ALT MAG Function (x5, x10, x20)
yball.gif (937 bytes) Vertical Mode Triggering
yball.gif (937 bytes) TV Synchronization
yball.gif (937 bytes) CH1 Signal Output, Z-axis Input
yball.gif (937 bytes) Buzzer Alarm & LED Indicators
yball.gif (937 bytes) Compact size (275W x 130H x 370D mm) and Front Panel Layout Groups for   
    easy to use
 
    SPECIFICATIONS


     CRT


Type


6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers. 8 x 10 DIV (1 DIV=1 cm)

Accelerating Potential GOS-6051/6050 approx.10kV
GOS-6031/6030 approx.2kV
INTEN and FOCUS Front panel control
Illumination Provided (GOS-6031/6051)
Trace Rotation Provided
Z-axis input Sensitivity: at least 5V
Polarity: positive going input decrease intensity
Usable frequency range: DC to 2MHz
Maximum input voltage: 30V (DC+AC peak) at 1kHz or less
GOS-6051/6050 Input impedance: approx. 33kΩ
GOS-6031/6030 Input impedance: approx. 47kΩ

     VERTICAL SYSTEM

Sensitivity and Accuracy 1mV ~ 2mV/DIV + 5%, 5mV ~ 20V/DIV + 3%, 14 calibrated steps in 1-2-5 sequence
Vernier Vertical Sensitivity Continuously variable to 1/2.5 or less panel indicate value
Bandwidth (-3dB) and Rise Time

Bandwidth(-3dB)

Rise Time

GOS-6051/6050

5mV ~ 20V/DIV

DC ~ 50MHz

Approx. 7nS

1mV ~ 2mV/DIV

DC ~ 7MHz

Approx. 50nS

GOS-6031/6030

5mV ~ 20V/DIV

DC ~ 30MHz

Approx. 11.67nS

1mV ~ 2mV/DIV

DC ~ 7MHz

Approx. 50nS

Maximum Input Voltage 400V (DC + AC peak) at 1kHz or less
Input Coupling AC, DC, GND
Input Impedance 1MΩ + 2% // approx. 25pF
Vertical Modes CH1, CH2, DUAL (CHOP, ALT), ADD, CH2 INV
CHOP Frequency Approx. 250kHz
Dynamic Range GOS-6031/6030:8 DIV at 20MHz, 6 DIV at 30MHz
GOS-6051/6050:8 DIV at 40MHz, 6 DIV at 50MHz

     HORIZONTAL SYSTEM

Sweep Time 0.2uS/DIV ~ 0.5S/DIV, 20 steps selectable in 1-2-5 sequence, continuous variable control between steps at least 1:2.5
Accuracy + 3%, + 5% at x5, x10 MAG. + 8% at x20 MAG
Sweep Magnification x5, x10, x20 MAG
Maximum Sweep Time
(at MAG)
GOD-6051/6050: 20nS/DIV (10nS/DIV are uncalibrated)
GOD-6031/6030: 100nS/DIV (10nS/DIV ~ 40nS/DIV are uncalibrated)
ALT-MAG Function Available

     TRIGGER

Trigger Modes AUTO, NORM, TV
Trigger Source VERT-MODE, CH1, CH2, LINE, EXT
Trigger Coupling AC, HFR, LFR, TV-V(-), TV-H(-)
Trigger Slope "+" or   "-" polarity
Trigger Sensitivity

GOS-6051/6050

20Hz ~ 5MHz

5MHz ~ 40MHz

40MHz ~ 50MHz

GOS-6031/6030

20Hz ~ 2MHz

2MHz ~ 20MHz

20MHz ~ 30MHz

CH1, CH2
0.5 DIV
1.5 DIV
2.0 DIV
VERT-MODE
2.0 DIV
3.0 DIV
3.5 DIV
EXT
200mV
800mV
1V
TV sync pulse more than 1 DIV (CH1, CH2, VERT-MODE) or 200mV(EXT)
External Trigger Input Input Impedance:Approx. 1MΩ // 25pF (AC coupling)
Max. input voltage:400V (DC + AC peak) at 1kHz
Hold-off Time

Variable


     X-Y OPERATION

Input X-axis:CH1;Y-axis:CH2
Sensitivity 1mV/DIV ~ 20V/DIV
Bandwidth X-axis:DC ~ 500kHz (-3dB)
Phase Difference 3deg or less from DC to 50kHz

     OUTPUT SIGNAL

Trigger Signal Output Voltage: approx. 20mV/DIV (with 50Ω terminated);
Bandwidth:50Hz to at least 5MHz
Calibrator Output Voltage:0.5V + 3%;Frequency:approx. 1kHz,  Square wave

     CURSOR READOUT

Panel Setting Display CH1/CH2 sensitivity, sweep time, trigger condition
Panel Setting Save & Recall (GOS-6031/6051) 10 sets
Cursor Measurement
(GOS-6031/6051)
Cursor measurement function:ΔV, ΔT, 1/ΔT
Cursor resolution:1/25 DIV;
Effective cursor range:vertial: + 3 DIV, horizontal: + 4 DIV
Frequency Counter
(GOS-6031/6051)
Display digits:Max. 6-digits decimel
Frequency range:GOS-6051:50Hz ~ 50MHz;Accuracy:+ 0.01%
Frequency range:GOS-6031:50Hz ~ 30MHz;Accuracy:+ 0.01%
Measuring sensitivity:more than 2 DIV (measuring source selected from CH1 or CH2 as synchronous signal sources)

     POWER SOURCE AC 100V/120V/ 230V + 10%, 50/60Hz

     ACCESSORIES Power cord x 1, Instruction manual x 1, Probes(10:1/1:1) x 2

     DIMENSIONS & WEIGHT 275(W) x 130(H) x 370(D) mm, Approx. 7.2kg

--------------------------------------------------------------------------------------------------------------------------------------------------------------------- TOP
.......................................................................................................................................................................................................................................................................

Copyright (C) 2006 SC INTERNATIONAL RESEARCH CO., LTD. All Rights Reserved.
63/2772 Rajpattana Road, Sapansung, Sapansung, Bangkok 10240
Tel. (66)0-2948-7398 Fax (66)0-2948-7398

Back to menu  |  Contact us for order